Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module

Distributed I/O System N Series N232x 32-Channel Digital Output Module

No.N232x
N232x 32-channel digital output modules for BL210-series couplers. N2321 provides PNP 24 VDC high-level outputs, while N2322 provides NPN 0 VDC low-level outputs, with 200 mA per channel, 2 kVrms isolation, LED indication, and DIN-35 rail mounting.
Description
N Series Distributed I/O

Plug. Wire.
Replace.

N232x digital output modules feature removable, pluggable terminals. Wire the terminal once. If a module needs replacement, remove the terminals, swap the module, and plug the terminals back in.

No rewiring. No relabeling. Reduced wiring-error risk. Minutes instead of hours.

32Digital output channels
2–5 minTypical swap time
200 mAMaximum per channel
8N-Series categories
N232x 32-channel digital output module
Removable terminalsWire once and reuse during replacement.
N2321 / N2322PNP and NPN versions for output selection.
DIN-35 mountBuilt for distributed industrial I/O systems.

Designed for installers

You have spent hours in cramped panels, relabeling and reconnecting wires. N232x solves that with removable, pluggable terminals.

Built for maintainability

Wire the terminal once. During replacement, pull off the terminals, swap the module, and reattach the same terminal blocks.

Part of a platform

N232x is an optional module for the N-Series distributed I/O system and must be used with a suitable fieldbus coupler, such as a BL210 Series coupler.

What makes N232x different

Removable terminals. 32 channels. Industrial reliability.

The N232x combines removable spring-cage terminals, 32 digital output channels, individual channel LEDs, electrical isolation, and industrial EMC protection.

🔌

Removable terminals

The field wires stay attached to the terminal block during replacement, dramatically simplifying service.

⚙️

Service efficiency

Replace a module in minutes instead of spending a long time removing, labeling, and reconnecting wires.

📦

32-channel output

Select N2321 for PNP high-level active output or N2322 for NPN low-level active output.

🛡️

Industrial-grade design

2 kVrms isolation, IP20 protection, EMC protection, and -20°C to 55°C operation.

N232x models

Choose PNP or NPN output.

N2321 provides 32-channel PNP output with high-level active 24 VDC output. N2322 provides 32-channel NPN output with low-level active 0 VDC output.

N2321 · PNP Output

High-level active, 24 VDC output

Designed for applications that require sourcing (PNP) digital outputs across 32 individually indicated channels.

32Output channels
200 mAMaximum per channel
24 VDCActive output level
DO1–DO32Individual LED indicators
ControllerField device
Controller
24 VDC
PNP · High-level active output
Maintenance comparison

The removable-terminal difference.

Compare replacement workflow, downtime, wiring-error risk, and maintenance requirements.

Traditional fixed-terminal I/O

Replacement workflowRemove every wire, label it, reconnect it, and then test for errors.
Typical downtime30–60 minutes per replacement.
Risk levelHigh risk of wiring mistakes and polarity errors.
Maintenance burdenUsually needs an electrician or trained technician.

N232x with removable terminals

Replacement workflowRemove the terminal block, swap the module, reconnect the terminal block, and finish.
Typical downtime2–5 minutes per replacement.
Risk levelLower risk because the field wires remain connected to the original terminal block.
Maintenance burdenCleaner maintenance and fewer service headaches.
Minutes instead of hours. No rewiring. No relabeling. Reduced wiring-error risk.
N-Series module family

More N-Series I/O module options.

The N-Series includes digital input, digital output, analog input, analog output, RTD, temperature, pulse, and power modules.

I/O modules can be arranged in different combinations within the distributed I/O station without grouping them by module type.

26 modules · 8 categories

6 modules

DI

+

Digital input options for NPN, PNP, and dry-contact sensing.

  • N116116CH DI Module (NPN)
  • N116216CH DI Module (PNP)
  • N116316CH DI Module (Dry Contact)
  • N132132CH DI Module (NPN)
  • N132232CH DI Module (PNP)
  • N132332CH DI Module (Dry Contact)

5 modules

DO

+

Digital and relay output options for discrete control.

  • N20848CH Relay Output Module
  • N216116CH DO Module (PNP)
  • N216216CH DO Module (NPN)

3 modules

AI

+

Analog input options for current and voltage acquisition.

  • N30464CH 16-bit AI Module, Differential Input, ±5V / ±10V
  • N30818CH 16-bit AI Module, Single-Ended Input, 0/4-20mA
  • N30838CH 16-bit AI Module, Single-Ended Input, 0-5V / 0-10V

2 modules

AO

+

Analog output options for current and voltage control.

  • N40818CH 16-bit AO Module, 0/4-20mA Output
  • N40868CH 16-bit AO Module, ±5V / ±10V Output
🌡

4 modules

RTD

+

RTD modules for PT100 and PT1000 temperature sensing.

  • N50414CH RTD Module, three-wire PT100
  • N50424CH RTD Module, three-wire PT1000
  • N50434CH RTD Module, four-wire PT100
  • N50444CH RTD Module, four-wire PT1000

2 modules

Temperature

+

Dedicated temperature modules for NTC and thermocouple signals.

  • N50858CH NTC Module
  • N50888CH TC Module

3 modules

Pulse

+

Pulse counting and pulse-output control modules.

  • N90813CH Pulse Counter + 5×DI
  • N90826CH Pulse Output + 2×DO
  • N90832CH Pulse Output (Pulse Count Control) + 4×DI + 2×DO

1 module

Power

+

Additional power support for larger N-Series stations.

  • N7021Power Module
💡
Important system note

When the number of selected N-Series I/O boards exceeds 20, an additional power module is required. If the number is less than 20, no extra power module is needed.

Recommended users

Who should use the N232x digital output module?

N232x fits distributed I/O installations that value serviceability and 32-channel discrete output control.

Maintenance teams

Cut down panel maintenance time and reduce wiring errors during module replacement.

System integrators

Build panels that are easier for your customers to maintain throughout the project lifecycle.

OEM manufacturers

Provide faster field replacement and lower support costs at customer sites.

Distributed I/O projects

Use N232x with a suitable N-Series fieldbus coupler, such as a BL210 Series coupler.

Technical specifications

N232x technical specifications.

Models, output characteristics, wiring requirements, environmental ratings, dimensions, and N-Series system compatibility.

32Digital output channels
200 mAMaximum output current per channel
2 kVrmsElectrical isolation
DIN-35Industrial rail installation

N2321 vs. N2322

N2321 is PNP high-level active with 24 VDC output. N2322 is NPN low-level active with 0 VDC output.

Shared 32-channel platform
Selection point N2321 N2322
Output type PNP / sourcing NPN / sinking
Active level High-level active Low-level active
Active output 24 VDC 0 VDC
Channels 32 channels 32 channels
Maximum current 200 mA per channel 200 mA per channel

Electrical specifications

Electrical data for N2321 and N2322.

01
ModelsN2321 PNP / N2322 NPN
Digital output channels32 channels
Maximum output current200 mA per channel
Internal bus power5 VDC, 27 mA
Electrical isolation2 kVrms
Channel indicationIndividual LED indicators for DO1 to DO32
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module
  • Distributed I/O System N Series N232x 32-Channel Digital Output Module,Distributed I/O System N Series N232x 32-Channel Digital Output Module

Want to get more information?

REQUEST A QUOTE
IIoT Gateway Manufacturer

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
FirstName *
LastName *
Email *
Message *
Code *
Verification Code
Leave a message
FirstName *
LastName *
Email *
Message *
Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.