Modbus to OPC UA bridge with expandable distributed I/O. Collect data via Modbus RTU or Modbus TCP, upload automatically to any OPC UA client — no coding, no complex mapping. Built-in RS485, dual Ethernet with switch, and support for up to 32 N Series I/O modules. Industrial-grade stability with auto-reconnect, automatic data frame correction, and reboot-free operation.
Direct connection to IT systems — no middleware needed
Standard OPC UA with encrypted transmission
Direct SCADA / MES / MOM / ERP connectivity
Standardized data modeling
Two‑way communication
🔐
Secure OPC UA Server
Native OPC UA with encrypted data transmission. Direct connection to SCADA, MES, MOM, ERP — no middleware, no vendor lock‑in.
IT/OT integration
🔌
Modbus Unified Gateway
Integrated RS485 (Modbus RTU master/slave) + Ethernet Modbus TCP acquisition. Bridge legacy devices to OPC UA in one step.
Modbus RTU/TCP → OPC UA
⚡
Industrial‑grade RS485
Strong anti‑interference, built for VFD‑dense, motor‑heavy, long‑cable factory floors. Rock‑solid signal in the harshest environments.
VFD · long cable · stable
🔗
Auto‑reconnect
Network drop, RS485 glitch, transient interference – automatically reconnects when link recovers. No manual intervention, no data loss.
unattended · self‑healing
🔄
Frame auto‑correction
Interference causes frame offset or corruption? The system detects and corrects automatically – no glitches, no false values.
data integrity
🖥️
BLRAT remote management
Built‑in BLRAT tool enables remote device monitoring, diagnostics, and configuration – reduce on‑site visits, simplify O&M across distributed sites.
remote O&M · centralized management
🌐
Dual‑port cascade
Built‑in switch function – simple wiring, save switches and cost. Ideal for long‑distance, multi‑node field networks.
simplified network · cost saver
📦
Tool‑free · detachable terminals
Terminal blocks separated from I/O modules. Replace modules without rewiring – reduce downtime, simplify maintenance.
swap modules · keep wires
🛡️
Industrial‑grade reliability
ESD Level 3 (±6kV/±8kV) · Surge Level 3 (1kV/2kV). Designed for harsh factory environments with stable 24/7 operation.
ESD L3 · Surge L3
🏭 Typical applications
🏭 SCADA & MES Integration🔋 New Energy & Battery🚗 Automotive Smart Manufacturing📦 Intelligent Warehousing☀️ Energy Monitoring & Solar🏢 Building Automation
👥Who uses it? What does it solve?
🏭 OEMs
⚠️ PLC I/O shortage · data upload to IT
✅ OPC UA direct to MES/ERP · flexible expansion
🔗 System Integrators
⚠️ Multi‑protocol devices · platform integration
✅ Modbus → OPC UA unified gateway · one system
⛑️ Engineering & O&M
⚠️ Legacy equipment · data silos · manual collection
✅ Standardized data · remote visibility · less downtime
☁️ Software & Platform
⚠️ Edge data quality · OT/IT compatibility
✅ Clean OPC UA data · ready for analytics and AI
📋 Core specifications
Power / consumption
24V DC · 76mA
CPU / Memory
300MHz · 64MB RAM · 128MB Flash
Ethernet
2× RJ45 (switch cascade) · 10/100M · dual‑port
RS485
Isolated · Modbus RTU master/slave
Protocols
OPC UA Server · Modbus TCP · HTTP · DHCP · DNS
I/O expansion
Up to 32 N‑series modules (DI/DO/AI/AO/RTD/TC/PWM)
Immunity level
ESD L3 (±6kV/±8kV) · Surge L3 (2kV/4kV)
Operating temperature
-20 ~ 55 °C (cold start -40°C)
Dimensions (W×D×H)
26 × 74.9 × 104.5 mm · ultra‑slim
Mounting / protection
DIN‑rail 35mm · IP20
Terminal blocks
Detachable · tool‑free wiring · AWG 22–14
💎Acquire · Convert · Upload — BL211 bridges the gap between field devices and IT systems. OPC UA native, encrypted, and ready for Industry 4.0.
N‑Series I/O · Quick Selector
Select coupler + add I/O modules as needed · auto power calculation